Unoccupied electronic states
isochromat or energy-resolved IPES
Material Analysis · Composition & Elemental
Characterise unoccupied electronic states, conduction-band onset and electron affinity, and changes in electronic structure with composition, interface, or treatment using a scope agreed around your sample and decision.
Why this service
Inverse Photoemission Spectroscopy is selected when the project needs defensible information on unoccupied electronic states, conduction-band onset and electron affinity, or changes in electronic…
isochromat or energy-resolved IPES
angle-dependent measurement where available
combined UPS/IPES band-alignment study
Choose the scope
The method, preparation route and reporting depth depend on what you need to decide.
unoccupied electronic states
conduction-band onset and electron affinity
changes in electronic structure with composition, interface, or treatment
Common outputs
Fields, conditions, processing and file formats are confirmed before work begins.
Inverse-photoemission spectrum reported with the agreed units, sample reference and measurement conditions.
Energy-referenced band onset and feature assignments supplied in a labelled format suitable for direct sample or condition comparison.
Acquisition geometry, resolution, and surface-preparation record provided with the processing basis and quality checks agreed during technical review.
Processed spectra included when selected in the confirmed reporting scope.
Sample requirements
Provide representative, clearly labelled samples and identify the decision, feature or comparison that matters.
| Suitable sample | Submission requirement | Planning note |
|---|---|---|
| Film / coating | Provide the coated substrate or a flat film with the test surface and coating side clearly marked. | State the substrate, nominal thickness and whether sectioning or mounting is permitted. |
| Test coupon / specimen | Provide labelled specimens prepared to the agreed geometry, orientation and surface condition. | Confirm the applicable standard, dimensions, loading direction and number of replicates. |
| Device / assembly | Provide a complete labelled device or assembly with drawings, interfaces and operating limits. | Confirm power, connections, operating state, access restrictions and permitted disassembly. |
Objective: state the decision, comparison or acceptance criterion the work must support.
Handling and access: declare hazards, instability, confidentiality, file constraints or special logistics before dispatch or transfer.
Questions and answers
Short answers to issues that can change preparation, scope, timing or interpretation.
Provide film / coating, test coupon / specimen, device / assembly as applicable. Exact quantity, dimensions and preparation are confirmed during technical review.
Choose the mode around the decision you need to make. For unoccupied electronic states, start with isochromat or energy-resolved IPES; add angle-dependent measurement where available when comparison or quantification is required.
Typical turnaround is 5 working days after sample acceptance and method confirmation.
The method is surface sensitive and susceptible to contamination and electron-beam damage. Availability is limited and energy resolution is typically lower than conventional photoemission.
Configure the service