Material Analysis · Composition & Elemental

Inverse Photoemission Spectroscopy (IPES)

Characterise unoccupied electronic states, conduction-band onset and electron affinity, and changes in electronic structure with composition, interface, or treatment using a scope agreed around your sample and decision.

  • Unoccupied electronic states
  • Conduction-band onset and electron affinity
  • Changes in electronic structure with…
  • Isochromat or energy-resolved IPES
Representative Inverse Photoemission Spectroscopy equipment selected for the TESTDOG service catalogue
Price
from£25
per sample, excl. VAT
Turnaround
5 working days
Preparation and scope dependent
Available platforms
SPECS PHOIBOS 225 IPES configuration
Typical outputs
Inverse-photoemission spectrumEnergy-referenced band onset and feature assignmentsAcquisition geometry, resolution, and surface-preparation recordProcessed spectra

Why this service

What IPES can help you understand

Inverse Photoemission Spectroscopy is selected when the project needs defensible information on unoccupied electronic states, conduction-band onset and electron affinity, or changes in electronic…

01

Unoccupied electronic states

isochromat or energy-resolved IPES

02

Conduction-band onset and electron affinity

angle-dependent measurement where available

03

Changes in electronic structure with composition, interface, or…

combined UPS/IPES band-alignment study

Choose the scope

Start from the question, not the tool

The method, preparation route and reporting depth depend on what you need to decide.

Isochromat or energy-resolved IPES

unoccupied electronic states

Best used when
unoccupied electronic states
Typical result
Inverse-photoemission spectrum
Preparation note
State the substrate, nominal thickness and whether sectioning or mounting is permitted.

Common outputs

A result package matched to the decision you need to make

Fields, conditions, processing and file formats are confirmed before work begins.

StandardInverse-photoemission spectrum

Inverse-photoemission spectrum reported with the agreed units, sample reference and measurement conditions.

StandardEnergy-referenced band onset and feature assignments

Energy-referenced band onset and feature assignments supplied in a labelled format suitable for direct sample or condition comparison.

OptionalAcquisition geometry, resolution, and surface-preparation record

Acquisition geometry, resolution, and surface-preparation record provided with the processing basis and quality checks agreed during technical review.

OptionalProcessed spectra

Processed spectra included when selected in the confirmed reporting scope.

Sample requirements

What to provide before work begins

Provide representative, clearly labelled samples and identify the decision, feature or comparison that matters.

Suitable sampleSubmission requirementPlanning note
Film / coatingProvide the coated substrate or a flat film with the test surface and coating side clearly marked.State the substrate, nominal thickness and whether sectioning or mounting is permitted.
Test coupon / specimenProvide labelled specimens prepared to the agreed geometry, orientation and surface condition.Confirm the applicable standard, dimensions, loading direction and number of replicates.
Device / assemblyProvide a complete labelled device or assembly with drawings, interfaces and operating limits.Confirm power, connections, operating state, access restrictions and permitted disassembly.

Objective: state the decision, comparison or acceptance criterion the work must support.

Handling and access: declare hazards, instability, confidentiality, file constraints or special logistics before dispatch or transfer.

Questions and answers

Common planning decisions

Short answers to issues that can change preparation, scope, timing or interpretation.

What should I send for Inverse Photoemission Spectroscopy?

Provide film / coating, test coupon / specimen, device / assembly as applicable. Exact quantity, dimensions and preparation are confirmed during technical review.

Which analysis option should I choose?

Choose the mode around the decision you need to make. For unoccupied electronic states, start with isochromat or energy-resolved IPES; add angle-dependent measurement where available when comparison or quantification is required.

How long will the test take?

Typical turnaround is 5 working days after sample acceptance and method confirmation.

What can limit the result?

The method is surface sensitive and susceptible to contamination and electron-beam damage. Availability is limited and energy resolution is typically lower than conventional photoemission.

Configure the service

Send the information needed to scope IPES correctly

  • Sample form, material, dimensions and quantity
  • Feature or decision the result must address
  • Required comparison, acceptance criterion or reference
  • Preferred output and reporting depth
IPES analysisfrom£25

Typical turnaround: 5 working days

Configure & Book