Mass change and thermal-event temperature
TG-FTIR
Material Analysis · Chromatography & Diagnostics
Characterise mass change and thermal-event temperature, evolved-gas identity and relative intensity, and decomposition, desorption, oxidation, and residue pathways using a scope agreed around your sample and decision.
Why this service
Thermal Analysis Evolved-Gas Analysis (TG-FTIR/MS/GC-MS) is selected when the project needs defensible information on mass change and thermal-event temperature, evolved-gas identity and relative…
TG-FTIR
TG-MS
TG-GC-MS
Choose the scope
The method, preparation route and reporting depth depend on what you need to decide.
mass change and thermal-event temperature
evolved-gas identity and relative intensity
decomposition, desorption, oxidation, and residue pathways
Common outputs
Fields, conditions, processing and file formats are confirmed before work begins.
TG/DTG and optional DSC curves reported with the agreed units, sample reference and measurement conditions.
Time/temperature-linked FTIR or MS traces supplied in a labelled format suitable for direct sample or condition comparison.
Identified evolved species and integrated interpretation provided with the processing basis and quality checks agreed during technical review.
Processed spectra included when selected in the confirmed reporting scope.
Sample requirements
Provide representative, clearly labelled samples and identify the decision, feature or comparison that matters.
| Suitable sample | Submission requirement | Planning note |
|---|---|---|
| Powder / particles | Provide a dry, homogeneous and clearly labelled sample in a sealed container. | Exact mass and any drying or dispersion step are confirmed after technical review. |
| Film / coating | Provide the coated substrate or a flat film with the test surface and coating side clearly marked. | State the substrate, nominal thickness and whether sectioning or mounting is permitted. |
| Gas / headspace | Provide the gas composition, concentration range, cylinder or sampling format and required pressure. | Gas compatibility, fittings, flow and safety controls are confirmed before acceptance. |
| Device / assembly | Provide a complete labelled device or assembly with drawings, interfaces and operating limits. | Confirm power, connections, operating state, access restrictions and permitted disassembly. |
Objective: state the decision, comparison or acceptance criterion the work must support.
Handling and access: declare hazards, instability, confidentiality, file constraints or special logistics before dispatch or transfer.
Questions and answers
Short answers to issues that can change preparation, scope, timing or interpretation.
Provide powder / particles, film / coating, gas / headspace, device / assembly as applicable. Exact quantity, dimensions and preparation are confirmed during technical review.
Choose the mode around the decision you need to make. For mass change and thermal-event temperature, start with TG-FTIR; add TG-MS when comparison or quantification is required.
Typical turnaround is 10 working days after sample acceptance and method confirmation.
Transfer lines cause delay, dilution, condensation, and selective loss. Gas signals are often semi-quantitative without compound-specific calibration.
Configure the service