Nanoscale chemical identity
point spectroscopy
Material Analysis · Structure & Spectroscopy
Characterise nanoscale chemical identity, topography and local mechanical response, and chemical-domain size and distribution using a scope agreed around your sample and decision.
Why this service
Optical Photothermal Infrared Spectroscopy is selected when the project needs defensible information on nanoscale chemical identity, topography and local mechanical response, or chemical-domain size and…
point spectroscopy
chemical imaging
correlative nanomechanical or electrical mapping
Choose the scope
The method, preparation route and reporting depth depend on what you need to decide.
nanoscale chemical identity
topography and local mechanical response
chemical-domain size and distribution
Common outputs
Fields, conditions, processing and file formats are confirmed before work begins.
AFM topography reported with the agreed units, sample reference and measurement conditions.
Point nano-IR spectra supplied in a labelled format suitable for direct sample or condition comparison.
Chemical-intensity maps and correlation overlays provided with the processing basis and quality checks agreed during technical review.
Processed spectra included when selected in the confirmed reporting scope.
Sample requirements
Provide representative, clearly labelled samples and identify the decision, feature or comparison that matters.
| Suitable sample | Submission requirement | Planning note |
|---|---|---|
| Powder / particles | Provide a dry, homogeneous and clearly labelled sample in a sealed container. | Exact mass and any drying or dispersion step are confirmed after technical review. |
| Film / coating | Provide the coated substrate or a flat film with the test surface and coating side clearly marked. | State the substrate, nominal thickness and whether sectioning or mounting is permitted. |
| Test coupon / specimen | Provide labelled specimens prepared to the agreed geometry, orientation and surface condition. | Confirm the applicable standard, dimensions, loading direction and number of replicates. |
| Solid / component | Provide a clean, stable and clearly labelled specimen with the target face or region identified. | Confirm dimensions, cutting permission and whether the original geometry must be preserved. |
Objective: state the decision, comparison or acceptance criterion the work must support.
Handling and access: declare hazards, instability, confidentiality, file constraints or special logistics before dispatch or transfer.
Questions and answers
Short answers to issues that can change preparation, scope, timing or interpretation.
Provide powder / particles, film / coating, test coupon / specimen, solid / component as applicable. Exact quantity, dimensions and preparation are confirmed during technical review.
Choose the mode around the decision you need to make. For nanoscale chemical identity, start with point spectroscopy; add chemical imaging when comparison or quantification is required.
Typical turnaround is 6 working days after sample acceptance and method confirmation.
Strong roughness, poor thermal contact, or weak absorption can reduce signal. Results sample a shallow local area and require representative site selection.
Configure the service