Performance Testing · Electrical & Electrochemical

Electrochemical Corrosion Testing

Quantify corrosion tendency and protection using open-circuit, polarisation and impedance measurements.

  • What are the corrosion potential and…
  • How effective is a coating or inhibitor?
  • How does corrosion behaviour evolve with…
  • Potentiodynamic polarisation
Potentiostat used for electrochemical corrosion testing
Price
from£45
per sample, excl. VAT
Turnaround
8 working days
Preparation and scope dependent
Available platforms
Gamry Interface 1010E
Typical outputs
Open-circuit potentialPolarisation or Tafel curveCorrosion current or polarisation resistanceNyquist and Bode plots

Why this service

What Electrochemical Corrosion Testing can help you understand

Electrochemical corrosion testing examines the response of a material or coating in a defined electrolyte. Tafel, linear polarisation resistance and EIS routes provide different information and are…

01

What are the corrosion potential and corrosion-current indicators?

Potentiodynamic polarisation

02

How effective is a coating or inhibitor?

Linear polarisation resistance

03

How does corrosion behaviour evolve with exposure time?

Corrosion EIS and exposure study

Choose the scope

Start from the question, not the tool

The method, preparation route and reporting depth depend on what you need to decide.

Potentiodynamic polarisation

What are the corrosion potential and corrosion-current indicators?

Best used when
What are the corrosion potential and corrosion-current indicators?
Typical result
Open-circuit potential
Preparation note
Declare biological hazards and confirm fixation, dehydration, temperature and disposal requirements.

Common outputs

A result package matched to the decision you need to make

Fields, conditions, processing and file formats are confirmed before work begins.

StandardOpen-circuit potential

Open-circuit potential reported with the agreed units, sample reference and measurement conditions.

StandardPolarisation or Tafel curve

Polarisation or Tafel curve supplied in a labelled format suitable for direct sample or condition comparison.

OptionalCorrosion current or polarisation resistance

Corrosion current or polarisation resistance provided with the processing basis and quality checks agreed during technical review.

OptionalNyquist and Bode plots

Nyquist and Bode plots included when selected in the confirmed reporting scope.

Sample requirements

What to provide before work begins

Provide representative, clearly labelled samples and identify the decision, feature or comparison that matters.

Suitable sampleSubmission requirementPlanning note
Biological / soft materialProvide fixed, preserved or otherwise stabilised material in the agreed container and medium.Declare biological hazards and confirm fixation, dehydration, temperature and disposal requirements.
Test coupon / specimenProvide labelled specimens prepared to the agreed geometry, orientation and surface condition.Confirm the applicable standard, dimensions, loading direction and number of replicates.
Device / assemblyProvide a complete labelled device or assembly with drawings, interfaces and operating limits.Confirm power, connections, operating state, access restrictions and permitted disassembly.

Objective: state the decision, comparison or acceptance criterion the work must support.

Handling and access: declare hazards, instability, confidentiality, file constraints or special logistics before dispatch or transfer.

Questions and answers

Common planning decisions

Short answers to issues that can change preparation, scope, timing or interpretation.

Which corrosion method should I choose?

Use the decision to choose: rapid tendency, rate indicator, coating barrier response or time-dependent degradation.

What is the typical turnaround?

Typical turnaround is 8 working days after sample acceptance and method confirmation.

Configure the service

Send the information needed to scope Electrochemical Corrosion Testing correctly

  • Sample form, material, dimensions and quantity
  • Feature or decision the result must address
  • Required comparison, acceptance criterion or reference
  • Preferred output and reporting depth
Electrochemical Corrosion Testingfrom£45

Typical turnaround: 8 working days