What efficiency, Voc, Jsc and fill factor does the device achieve?
Illuminated J-V
Performance Testing · Electrical & Electrochemical
Measure illuminated and dark J-V response, photovoltaic efficiency and device-to-device variation.
Why this service
Solar-cell I-V testing sweeps voltage while current is measured under controlled illumination and, where selected, in the dark. Reliable performance metrics depend on calibrated irradiance, active area,…
Illuminated J-V
Dark and light J-V
Pixel, hysteresis or stability comparison
Choose the scope
The method, preparation route and reporting depth depend on what you need to decide.
What efficiency, Voc, Jsc and fill factor does the device achieve?
Is hysteresis or series/shunt resistance limiting performance?
How consistent are pixels, devices or ageing conditions?
Common outputs
Fields, conditions, processing and file formats are confirmed before work begins.
J-V curve reported with the agreed units, sample reference and measurement conditions.
Voc, Jsc, fill factor and efficiency supplied in a labelled format suitable for direct sample or condition comparison.
Series and shunt resistance indicators provided with the processing basis and quality checks agreed during technical review.
Dark, reverse-scan or stability comparison included when selected in the confirmed reporting scope.
Sample requirements
Provide representative, clearly labelled samples and identify the decision, feature or comparison that matters.
| Suitable sample | Submission requirement | Planning note |
|---|---|---|
| Biological / soft material | Provide fixed, preserved or otherwise stabilised material in the agreed container and medium. | Declare biological hazards and confirm fixation, dehydration, temperature and disposal requirements. |
| Test coupon / specimen | Provide labelled specimens prepared to the agreed geometry, orientation and surface condition. | Confirm the applicable standard, dimensions, loading direction and number of replicates. |
| Device / assembly | Provide a complete labelled device or assembly with drawings, interfaces and operating limits. | Confirm power, connections, operating state, access restrictions and permitted disassembly. |
Objective: state the decision, comparison or acceptance criterion the work must support.
Handling and access: declare hazards, instability, confidentiality, file constraints or special logistics before dispatch or transfer.
Questions and answers
Short answers to issues that can change preparation, scope, timing or interpretation.
No. EQE is a separate optical-spectral measurement unless explicitly added.
Typical turnaround is 8 working days after sample acceptance and method confirmation.
Configure the service